Frequently asked questions
Answers to the questions our customers ask most often – about the design, drawings, heat pumps and payment.
Price and turnaround
How much does an underfloor heating design cost?
The price depends on the floor area of the building (prices incl. VAT): up to 100 m² – £169, 100–150 m² – £199, 150–200 m² – £219, 200–250 m² – £259, 250–300 m² – £279. Over 300 m² we quote individually. The heat loss calculation is included.
How long does the design take?
Normally up to 10 working days working days from receipt of payment. If you are in a hurry, choose the express option – design in 48 working hours for an extra £69 incl. VAT.
Does the price depend on the number of floors?
No. The number of storeys does not affect the price – it only depends on the floor area of the building.
Does the 48 h express design have the same scope?
Yes. The scope is exactly the same as a standard design – only the turnaround is shorter.
My house is very large or unusual. How do you price it?
Fill in the form and attach the drawings. Once we have reviewed them we will send you a price for the design.
What's included
What do I get in the design?
Around 22 pages of drawings and calculations: floor plans with the loop layout, a system schematic, heat losses for the building and every room, a manifold sheet with settings, installation parameters for every room, pipe coil allocation, lists of pipes, fittings, controls and all other components, and room sheets. You can see sample pages under “What's included”.
In what format will I receive the design?
We send the design by email as a PDF containing all calculations and lists. We prepare the design in Polish and include an automatic AI translation into English. On request we can also provide the floor plans as DWG.
What language is the design in?
Our engineers prepare the design in Polish. You also receive an automatic translation into English, produced with AI and labelled as such. All numbers, dimensions and drawings are identical in both versions – only the text is translated. The Polish original is the binding version.
Do I really need a design? My installer says he can do it without one.
Laying pipes by rule of thumb, e.g. 100 mm centres everywhere, risks under- or overheated rooms and unnecessarily expensive materials. A design calculates the heat loss of every room and sizes the loops to match – it usually pays for itself when you buy the materials.
Is the heat loss calculation included?
Yes. A room-by-room heat loss calculation to BS EN 12831 is included in the price – you do not pay extra for it.
Does the design include flow meter settings?
Yes. The manifold sheet contains the balancing settings calculated separately for every loop.
How is a bespoke design different from an online calculator?
A bespoke design is based on the details from your form. It takes into account floor finishes, the orientation of the building and your preferences – unlike off-the-shelf layouts or quick calculators that use average values and general manufacturer guidance.
Does the design account for the kitchen, fitted furniture and windows?
Yes. The design takes fixed units and large glazed areas into account. Where the calculations require it, we add perimeter zones with tighter pipe spacing under windows.
Drawings and information
What do I need to provide for the design?
Just fill in the enquiry form (5 steps): contact details, heat source, building details, floor plans and sections (a sketch of the loops is optional), the build-up of floors, ceilings, walls, roof and windows, plus information on ventilation and controls.
Is a photo of a paper plan enough? Do I need a DWG file?
We accept floor plans as DWG, PDF, JPG and PNG. A photo of a paper plan is also fine if it is taken straight on with the sheet laid flat. The better the drawings, the more accurate the design.
I don't have a floor plan because the house is old. What now?
You can draw a plan in a free floor plan app (e.g. Floorplanner) or send us a hand sketch with dimensions – for an extra fee we will turn it into a plan for the design.
I've moved some walls compared with the architect's plan. How do I tell you?
If the outline of the building is unchanged and only individual walls have moved, simply mark the change by hand on the plan and add the new dimensions.
Is a remote design without a site visit just as good?
Yes. The design is based on your building drawings, which represent your building accurately.
Heat pumps, loops and controls
Is the design suitable for a heat pump?
Yes. The design is based on the heat source you choose in the form – including a heat pump.
What flow temperature do you assume with a heat pump?
We calculate the flow temperature for the climate at your location (design outdoor temperature) and always optimise it for running costs.
Does the design size the heat pump or boiler?
The design includes the heat loss of the whole building. That figure is what your heat source must cover – use it to choose your heat pump or boiler.
Is underfloor heating a must with a heat pump?
It is not compulsory, but for low-temperature heat sources such as heat pumps, underfloor heating is the most efficient and cost-effective option.
Can a towel rail and the garage be on the same system as the underfloor heating?
Yes, that is possible. With a heat pump, however, a wet towel rail gives very little output, so in that case we suggest an electric towel rail.
Which pipe spacing: 100, 150 or 200 mm?
There is no single right spacing. We choose it for each room based on its heat loss, use and area, and the temperature of the heat source – including heat pumps.
What is the maximum length of a loop?
There is no golden rule. The maximum length depends on the loop layout, which determines the pressure drop – so we set it individually in the design.
How many loops in a large living room – and do they have to be the same length?
The number of loops depends on the size of the room. Length is secondary – what matters most is hydraulic balancing of the flows.
Spiral or serpentine – how should the pipes be laid?
In most cases a spiral (bifilar) layout is the best solution.
Does the design take the floor finish into account (tiles, laminate, wood, vinyl)?
Yes. You enter the floor finishes in the form and the design accounts for them.
Do I need a thermostat in every room?
Not necessarily. With a bespoke design the heating can be controlled by the heat pump's flow temperature alone. Room thermostats do, however, add comfort and let you set a different temperature in each room.
How do I set the flow meters? Should all loops have the same flow?
Set the flow meters according to the design – the flow for every loop is calculated individually.
One manifold or two – and where should it go?
The number of manifolds and their position depend on the building – we decide them individually in the design.
Do I need a mixing (pump) unit?
That depends on the heat source and on the size and type of the heating system.
Which pipes are best for underfloor heating?
The most common choice is 16 mm PE-RT pipe with an EVOH oxygen barrier.
Wired or wireless thermostats?
Both are possible. For wired controls, the guidance for your electrician is in the technical documentation of the chosen manufacturer.
Materials and installation
Do you also supply materials or install the system?
No – in the UK we offer the design only. You receive a complete bill of materials so you can order from any supplier you like and your installer can fit the system.
Can I install the underfloor heating myself using the design?
Yes. The design includes the installation parameters for every room, the pipe coil allocation and the manifold settings.
Can I use pipes from a different manufacturer?
Yes, alternatives are fine – they should be technically equivalent (same diameter and comparable specification).
Can you help with questions during installation?
Yes. Just email us – this support is free of charge.
Terms and payment
Can I change something after receiving the design?
Yes. One free round of changes and corrections is included – we make them within 72 working hours. Further changes, or changes due to incorrect information, may be charged.
Is the design a statutory or certification document?
No. It is an underfloor heating design for installation. It does not replace documents for planning, Building Regulations or grant schemes that must be signed off by a UK-registered professional.
How do I pay – and will I get an invoice?
Once you accept the quote, we send you bank details for a transfer in pounds sterling. After payment you receive an invoice. All prices are final prices including VAT; our service is for private customers.
Can't find your question? Write to us using the contact form.